| Power Supply | 230 VAC -15% + 10% 50Hz |
| Output Voltage | 13.8 V |
| Board Power Consumption | 87mA 18V~ / 90mA 18V~ |
| Fuse | F500mAL 250V |
| Wired Zones | 4-12 (Double/Triple EOL) + 2 zones per keypad (max. 4) |
| Wireless Zones | 64 |
| Output Ports (Outputs) | 1 (expandable to 8) |
| User Codes | 32 |
| Protection Areas (Areas) | 4 |
| Groups | 4 |
| Keypads / Tag Readers Limit | 4 / 4 |
| Event Buffer (Log Events) | 1000 records |
| Communication Numbers | 8 (SMS/Private call) + 8 (CMS) |
| Voltage Range | 9 - 16 V |
| Max. Absorption | 0.1A |
| Max. Output Current | 1.1A |
| Max. Ripple Voltage | 400mV |
| Max. Battery Charging Current | 500mA |
| Compatible Backup Battery | 12V 7Ah or 12V 17Ah |
| Operating Temperature | -10°C to +40°C |
| Maximum Humidity | 75% (non-condensing) |
| Dimensions (H x L x D) | 255 x 300 x 88 mm |
| Weight | 1.5 kg |